Tulsa Plumbing and Remodeling service van parked on a residential street with the phone number on the side

Noritz Tankless Error Codes: What They Mean and What to Check

Tulsa Plumbing and Remodeling service van parked on a residential street with the phone number on the side

Your Noritz tankless is flashing a code and there’s no hot water. Before you do anything else, write down the code and the model number off the rating plate on the side of the heater.

This post goes through the codes in Noritz’s owner’s guides for its tankless models: what each one means, what you can check yourself, and which ones need a licensed plumber. Some of them turn out to be something you can check yourself in five minutes without paying us a dime.

Read This First

This is a guide to Noritz’s manuals, not a replacement for them. Codes and steps can differ from one model to the next, so if anything here disagrees with the manual for your unit, go with the manual.

Noritz draws its own line. Its owner’s guides say installation and service must be done by a qualified installer, service agency or the gas supplier, and to contact a qualified service technician for any repairs, service or maintenance. Its newest guide adds a once a year check by a qualified service technician, and an older one says not to take the heater apart, repair it or modify it yourself. We hold to that line all the way through this post.

If you smell gas, leave first, then call ONG at 800-458-4251. Noritz’s manual adds: don’t try to light any appliance, don’t touch an electrical switch, and don’t use a phone in the building. Call from a neighbor’s phone.

If any part of the heater has been under water, don’t use it. Noritz says to call a qualified service technician right away to inspect it and replace any damaged parts.

And in an earthquake, a tornado or a fire, or if you notice abnormal combustion or odors, Noritz’s steps are: turn off the hot water, turn off the power to the heater, close the gas and water valves, and call for service.

Find Your Model and Write Down the Code

The model and serial number are on the rating plate on the side of the heater. On the EZ and NRCR, Heater Info in the menu shows them too, and the error history shows the last eight codes. Noritz will also ask whether it runs on natural gas or propane.

Noritz’s codes depend on the family, so this post has one chart for each:

  • EZ and NRCR: the newest condensing models, the EZ71DV, EZ98DV and EZ111DV and the NRCR92DV and NRCR111DV with a built in recirculation pump. Noritz’s site serves the same documents for the EZTR50 and EZTR75.
  • NR, NRC and EZTR40: the NR83, NR98, NR501 and NR662, the condensing NRC98, NRC111, NRC711 and NRC661A, and the EZTR40.
  • NRCB: the combi boilers that heat the house and the water.

On the EZ and NRCR, the display turns red and the code blinks. NR and NRC models with a remote show a two digit code, and models with a display window can show three digits, like 901 or 902.

If a code isn’t in the chart for your model, or it comes back after the steps below, Noritz says to contact Noritz America.

Check the Basics First

Noritz’s troubleshooting list starts with the basics. When a faucet gets no hot water, or no water at all, it asks:

  • Are the gas and water supply valves fully open?
  • Is the water supply cut off?
  • Is the faucet open far enough? The EZ needs 0.4 gallons a minute to start heating and stops below 0.26, so open it more or open another one.
  • Is the gas off at the meter? Do your other gas appliances work? On propane, is there gas in the tank?
  • Is the water filter clogged? More on that filter below.
  • Is the power button on?
  • Is the heater frozen?
  • On a new install, are the plumbing lines reversed or crossed? That’s the installer’s problem.

If a code keeps coming back after the basics check out, find it in the chart below. A unit that keeps throwing codes is often an install problem: an undersized gas line, the wrong vent, no isolation valves.

Clearing a Code

On the EZ and NRCR, Noritz says an 11 clears when you close the hot faucet and open it again, or when you turn the power button off and on.

On NR, NRC and EZTR40 models, turn the heater off with the power button on the remote, or unplug it if it has no remote, open a hot faucet, and turn the heater back on. If the blinking number doesn’t come back, the problem is solved.

If the code comes back, Noritz’s guides say to contact Noritz America Technical Support at 1-866-766-7489.

Noritz Error Codes

Here are the codes in Noritz’s owner’s guides, in plain English, plus a few from its installation manuals that owners can see. Where it says to call, that means a licensed plumber, and you can reach us at (918) 800-4426.

EZ and NRCR

CodeWhat it meansWhat you can check
06, 061, 062A recirculation problem, on NRCR models. Noritz’s installation manual calls it low recirculation flow, a warning that lets the heater keep running.Noritz says to check the return line filter and the crossover valve’s filter. We recommend a plumber for that.
11The burner didn’t light.Make sure the gas valve to the heater is open, then clear the code. On a new install there may be air in the gas line. If it comes back, call.
13A carbon monoxide alarm wired to the heater went off. It’s in Noritz’s installation manual.Follow the instructions that came with your carbon monoxide alarm, then call.
29An external condensate pump wired to the heater was triggered. It’s in Noritz’s installation manual.Call a licensed plumber.
41Can show while the heater is being drained. Noritz says that isn’t a malfunction.Nothing, if the heater is being drained. Otherwise, call.
63No recirculation flow, on NRCR models. It’s in Noritz’s installation manual.Call a licensed plumber.
73, 731A setting doesn’t match the vent. It’s in Noritz’s installation manual.Call a licensed plumber.
90, 901, 902Abnormal combustion. Noritz lists a clogged air supply vent (when the heater takes its air from indoors), a clogged exhaust vent, low gas pressure or a clogged condensate drain.Check the vents for anything blocking them, and the condensate drain for a clog or ice. Gas pressure is for a professional. If it stays, call.
91The gas conversion wasn’t done right.Call the installer.
121, 122The flame went out. It’s in Noritz’s installation manual.Call a licensed plumber.
C1 and a numberThe descaling reminder: time to flush the heat exchanger. It’s off from the factory, so it only shows if someone turned it on.Call to schedule the flush.

NR, NRC and EZTR40

CodeWhat it meansWhat you can check
11The burner didn’t light.Make sure the gas valve to the heater is open, then clear the code. If it comes back, call.
29The condensate trap or drain pipe is clogged, on condensing NRC and EZTR40 models.Check whether the condensate drain pipe is clogged or frozen. If the code stays, call.
73, 733The settings switches inside the heater were changed with the power on. It’s in Noritz’s installation manuals.Call a licensed plumber.
90Abnormal combustion. Depending on the model, Noritz points to a clogged air supply vent or air inlet filter, or to low gas supply pressure.On models with an air inlet filter or an indoor air supply, Noritz says to clean it. See the air filter section below. Gas pressure is for a professional. If it stays, call.
901, 903, 908Abnormal combustion, on models with a display window. On the EZTR40, Noritz points to a clogged air inlet filter, and on the NRC711 and NRC661A, to a clogged air supply vent when the heater takes its air from indoors.On those models, Noritz says to clean it. See the air filter section below. If it stays, call.
902Abnormal combustion from low gas supply pressure, on models with a display window.Have a professional check the gas pressure. Call.
94, 941, 942The exhaust is too hot, on the EZTR40. 941 is a warning, and the heater keeps running.Call a licensed plumber.
99Abnormal combustion.Call a licensed plumber.
C1 to C4, with or without a digit or letter afterThe heater found scale building up in the heat exchanger. It’s a warning, and the heater will shut off before long.It needs a flush. Call. If it shuts off first, Noritz says disconnecting the power lets it run for now.
CF, with or without a digit or letter afterScale was found so many times that the heater locked itself.It needs a flush. Call.
CCC, FCC, C60 to C00Not a fault. These show while the heat exchanger is being flushed.Nothing, during a flush. Otherwise, call.
Two flashing dotsOn models with a display window, the water coming out is colder than the setting.Call a licensed plumber.
Three flashing dotsNot a fault. With low flow and warm incoming water, the heater sometimes doesn’t fire.Nothing. Noritz says it isn’t a fault.

NRCB Combi Boilers

CodeWhat it meansWhat you can check
11The burner didn’t light.Make sure the gas valve is open, then clear the code. If it comes back, call.
F11On combi boilers linked together, Noritz’s installation manual says air may be trapped in the gas line.Call a licensed plumber.
20The high limit switch on the primary heat exchanger tripped.Noritz points to air in the heating system or in the internal pump, and says not to ignore it. Call.
64The internal pump is air locked.Noritz says to contact its agent to clear it. Call.
88The service reminder.Call to schedule service.
90Abnormal combustion: a clogged air supply vent, a clogged exhaust vent, low gas pressure or a clogged condensate drain.Check the vents for anything blocking them, and the condensate drain for a clog or ice. Gas pressure is for a professional. If it stays, call.

Codes You Can Usually Check Yourself

It’s a spectrum. A one time ignition lockout, a scale related flow code or a fouled vent termination outside are a reset, a descaling or a cleaning.

11: The Burner Didn’t Light

Start with the gas. Noritz’s first check for 11 is whether the gas valve to the heater is open. On a new install, it says there may be air in the gas line, so reset the heater and try again, and have a professional check the gas pressure if it keeps failing.

If it keeps coming back, call us. An undersized gas line is one of the install problems behind a unit that keeps throwing codes. Noritz says its EZ and NRCR models can work on a half inch gas pipe, within the limits in its installation manual, and checking that is a job for us. We never want you doing gas yourself.

Noritz also says these heaters have no pilot, so don’t try to light the burner by hand. And turn the gas valve knob by hand only, never with tools. If it won’t turn by hand, Noritz says not to force it and to call a qualified service technician.

90 and 29: Vents and the Condensate Drain

On the EZ and NRCR, Noritz’s list for 90 starts with the vents: the air supply vent, if the heater takes its air from indoors, and the exhaust vent. Look for anything blocking them. A tankless has its own vent and a matching air intake, usually PVC or stainless out a side wall. Go look at where they come out.

Its list also includes the condensate drain, and on condensing NRC and EZTR40 models that has its own code, 29. Check whether the drain line is clogged or frozen. If the code stays after that, call. Low gas pressure, the other cause on Noritz’s list, is for a professional.

When it snows, Noritz says to check the exhaust vent terminal for blockage. And it says not to use the heater if the intake or exhaust pipe has come apart, has holes, is clogged or is corroded.

Codes That Need a Plumber

For the rest, Noritz’s guides say to contact the installer, a Noritz agent or Noritz America: abnormal combustion (99), exhaust temperature (94, 941 and 942), the gas conversion (91), water colder than the setting (two flashing dots) and the combi boilers’ air locked pump (64). The codes that come from Noritz’s installation manuals (13 and 29 on the EZ and NRCR, 63, 73, 731, 733, 121, 122 and F11) are for a plumber too, and so is the combi boilers’ heat exchanger high limit (20), which Noritz says not to ignore.

When you contact Noritz, it asks for the model, the serial number and the gas type. Have those and the code ready for us too.

Heat exchanger, gas valve, control board and overheat faults are the other end of the spectrum, and on our own jobs those have run fifteen hundred to three thousand.

The C Codes: Scale

C codes are about scale, and they mean different things on different generations. On the EZ and NRCR, C1 and a number is a descaling reminder that’s off from the factory, and it means it’s time to flush. On NR, NRC and EZTR40 models, C1 through C4 means the heater found scale building up, and it will shut off before long. CF means it found scale so many times that it locked itself.

Either way it needs a flush. Noritz says that if an NR, NRC or EZTR40 model shuts off from scale, disconnecting the power lets it run for now. Its flushing procedure is written for a qualified service professional or an authorized Noritz service representative, so that part is ours.

Noritz’s Periodic Checks

Noritz’s owner’s guides list periodic checks. Its newest guide says a qualified service technician should do them once a year, and its older guides frame the same checks for owners. We recommend a plumber. If you’re handy, these are the ones you can see to from outside the heater, and if you do them yourself, follow your guide exactly. The risk is yours:

  • If the heater takes its air from indoors, check the air supply vent for dust, oil or other build up, and clean it with a vacuum or a damp towel. Noritz says not to remove the inlet screen and air screen completely.
  • Check the exhaust vent and its terminal for dust and soot.
  • Listen for abnormal sounds, and look for discoloration or damage on the outside.
  • Check the heater and the piping for water leaks.
  • Check that the condensate drain pipe isn’t blocked where it discharges.
  • Keep laundry, newspaper, wood, oil, spray cans and anything else that burns away from the heater and the vent terminal.

Noritz recommends setting up the once a year check with a service contractor. And if the temperature and pressure relief valve drips or leaks, it says to have a qualified service technician replace it.

The Water Filter

The water filter is built into the drain valve at the cold water inlet, and Noritz says to clean it as often as your water requires. We recommend having a plumber do it. Noritz lists it as something you can do yourself, though, so if you’re handy, follow its steps exactly. On the EZ and NRCR: turn the heater off and let it cool, close the hot water valve and the water supply valve (and the hot water return valve on an NRCR), and with a bucket ready, take out the drain valve. Noritz says up to 0.74 gallons of water may come out. Clean the filter with a brush under running water, put it back, open the valves, and make sure it doesn’t leak.

Noritz also notes not to lose the o-ring. NR, NRC and EZTR40 models have their own steps in their guides. If you do it yourself, the risk is yours.

The Air Inlet Filter

The EZTR40 and the NR98SV have an air inlet filter. Noritz says to check it for dust and trash and clear it with a vacuum, and not to remove the filter. If it’s been removed or damaged, it says to contact Noritz America.

Scale and Tulsa Water

Noritz’s guides say water over 12 grains per gallon of hardness, 200 mg/L, needs treatment, and its newest guide recommends a water softener or scale inhibitor. Its installation manual goes further: from moderately hard water, 3 grains per gallon and up, it calls for a scale shield or a water softener, and a flush once a year if there’s no treatment device.

In Tulsa that matters. Our water is hard, and the scale it leaves narrows the heat exchanger until you get flow codes and an early failure. Descaling is maintenance you have to keep up with, and we do it in house.

Winter: Keep It Plugged In

Noritz’s freeze protection runs whether the power button is on or off, but not when the heater is unplugged. Noritz says it protects the inside of the heater down to 30 below zero on a direct vent install and 4 below on an outdoor one, not counting wind, and that a heater taking its air from indoors needs the room above freezing.

That doesn’t cover the plumbing outside the heater. Noritz says to protect it with insulation, heat tape or pipe covers.

Noritz says the heater must stay plugged in. If it gets unplugged, it says to drain it completely and blow the water out of its piping with an air compressor. If you aren’t comfortable with that, call us.

For extreme cold, when the outside temperature with wind chill drops below 30 below zero on a direct vent install or 4 below on an outdoor one, Noritz gives steps: turn off the power button, close the gas valve, set any mixing valve to its highest level, and keep a small stream of hot water running, about a fifth of an inch thick. Check it again after 30 minutes. Before you use the heater again, set any mixing valves and faucets back where they were so nobody gets scalded.

If it’s already frozen, Noritz says don’t use it: close the gas and water valves, turn off the power button, open the water supply valve now and then to see whether water runs, and check for leaks before you use it again.

Do’s and Don’ts

Do

  • Write down the code and the model and serial number off the rating plate.
  • Check the basics first: power, the gas and water valves, and the faucet open far enough.
  • Keep the vents clear, and check the exhaust terminal when it snows.
  • Keep the water filter clean. We recommend a plumber, though Noritz lists it as something you can do yourself.
  • Have a qualified technician check the heater once a year. Noritz recommends it.
  • Keep up with flushing. In Tulsa it isn’t a suggestion.
  • Keep it plugged in all winter.
  • Put in a carbon monoxide alarm. Noritz recommends one, and its EZ installation manual says to put it in the same room as the heater when the heater takes its air from indoors.

Don’t

  • Don’t keep resetting a code that keeps coming back.
  • Don’t take the heater apart, repair it or modify it yourself.
  • Don’t try to light the burner by hand.
  • Don’t use tools on the gas valve.
  • Don’t use it if any part has been under water.
  • Don’t use it if the vent pipe has come apart, has holes, is clogged or is corroded.
  • Don’t keep anything that burns near it.
  • Other than turning the gas shutoff valve, don’t touch the gas. Call a licensed plumber.

What It Costs

On our price list, tankless water heater repair runs $650 to $1,225, and tankless descaling runs $425 to $850.

Tell us the code and the model number when you book.

Noritz’s Manuals and Support

Everything in the charts comes from Noritz’s own documents, and these are the ones worth keeping:

  • Noritz EZ and NRCR owner’s guide: SBB81M1, revised October 2025, for the EZ71DV, EZ98DV, EZ111DV, NRCR92DV and NRCR111DV. Maintenance starts on page 26, and the error codes are on page 31.
  • Noritz NRC98 owner’s guide: one of the older guides. Its error codes are on page 28.
  • Noritz’s manuals page, for the guide that matches your model.
  • Noritz America Technical Support: 1-866-766-7489.
  • ONG, if you smell gas: 800-458-4251.

Noritz keeps its service manuals for its own trained service reps. We checked this post against the owner’s guides and installation manuals on Noritz’s site in November 2026, so if yours is a different version, go with yours.

Call Us With the Code

We service every brand, and around Tulsa we see Navien, Rinnai, Rheem, Noritz and A.O. Smith most. Our error code guides for Navien, Rinnai, A.O. Smith, Rheem and Takagi cover the others, and our tankless error codes page shows which codes mean the same thing across brands.

Call us at (918) 800-4426 with the code and the model number. Our tankless water heater repair page has more on what we do.