A.O. Smith Tankless Error Codes: What They Mean and What to Check

Tulsa Plumbing and Remodeling service van parked on a residential street under a red fall tree

Your A.O. Smith tankless is flashing an E code and there’s no hot water. Before you do anything else, write down the code and the model number off the data plate.

This post goes through every code in the error code table of A.O. Smith’s manual for its Adapt+ condensing tankless: what each one means, what you can check yourself, and which ones need a licensed plumber. Some of them turn out to be something you can check yourself in five minutes without paying us a dime.

Read This First

This is a guide to A.O. Smith’s manual, not a replacement for it. Codes and steps can differ from one model to the next, so if anything here disagrees with the manual for your unit, go with the manual.

A.O. Smith’s manual starts with its own line: if you have trouble following the directions, or aren’t sure you can safely and properly do the work yourself, call A.O. Smith’s Technical Assistance Hotline. It also recommends having the unit checked once a year by a licensed technician, and says any repairs should be done by one. We hold to that line all the way through this post.

If you smell gas, leave first, then call ONG at 800-458-4251. A.O. Smith’s manual adds: don’t try to start the water heater, don’t touch an electrical switch, and don’t use a phone in the building. Call from a neighbor’s phone.

If any part of it has been under water, don’t use it. A.O. Smith says a flooded water heater has to be replaced, not repaired.

Find Your Model and Write Down the Code

The model number is on the data plate on the right side of the unit. The codes in this post come from A.O. Smith’s installation and use and care guide for the THR-160, THR-180 and THR-199. A.O. Smith’s site lists them as the Adapt+ Premium Condensing line, model numbers ATHR-160, ATHR-180 and ATHR-199, each in an M version and an X3 version.

A.O. Smith makes other tankless lines, like the Adapt SC, the Adapt NC and the ProLine XE, and each one has its own manual. If your model isn’t one of these, its codes can be different, so get its manual from A.O. Smith’s site, linked at the bottom of this post.

On these models the display flashes E and a three digit number, with leading zeros, like E002. If your heaters are linked together, the main unit alternates between the number of the heater with the problem and its code.

Check the Basics First

A.O. Smith’s troubleshooting chart starts with the basics. When a faucet gets no hot water, it asks:

  • Does the heater have power? It plugs into a grounded 120 volt outlet, though some are wired in.
  • Is it on? If the display is blank and pressing the Up button shows nothing, press On/Off.
  • Is the gas valve to the heater fully open, and on propane, is there gas in the tank?
  • Is the water supply valve fully open? A.O. Smith also asks whether the filter on the cold water inlet is clean. More on that filter below.
  • Is the faucet open far enough to pull at least 0.4 gallons a minute through the heater?
  • Is the unit frozen?

If a code keeps coming back after the basics check out, find it in the chart below. A unit that keeps throwing codes is often an install problem: an undersized gas line, the wrong vent, no isolation valves.

A.O. Smith Adapt+ Error Codes

Here’s every code in table 24 of A.O. Smith’s manual, in plain English. Where it says to call, that means a licensed plumber. A.O. Smith’s customer service line for gas tankless is 877-556-4549, and you can call us at (918) 800-4426.

CodeWhat it meansWhat you can check
E002A high limit switch tripped. These are the heater’s high temperature shutoffs, one on the water outlet and one on the burner door.Call a licensed plumber.
E006A hardware problem with the circuit board.Call a licensed plumber.
E010The circuit board is seeing the wrong power frequency.Call a licensed plumber.
E011A memory problem on the circuit board. The heater keeps running, but the recirculation pump shuts off.Call a licensed plumber.
E036Flame failure. The flame went out.Make sure the gas valve to the heater is fully open. Then call.
E037False flame detection. The heater sensed a flame that shouldn’t be there.Shut the heater off and call.
E038Ignition failure. The burner didn’t light.Make sure the gas valve to the heater is fully open, and on propane, that the tank has gas. Then call.
E041The water coming out is too hot.Call a licensed plumber.
E045The clock battery on the circuit board is low.If it showed up right after the power came back on, A.O. Smith says to ignore it. Otherwise call.
E049The exhaust temperature sensor failed.Call a licensed plumber.
E050The inlet water temperature sensor failed.Call a licensed plumber.
E051The outlet water temperature sensor failed.Call a licensed plumber.
E052The heat exchanger temperature sensor failed.Call a licensed plumber.
E383The water coming in is hotter than the temperature setting, or its sensor is reading wrong.Call a licensed plumber.
E384False flame detection.If you can see a flame through the sight glass, shut off the gas to the heater and call. Don’t use it until it’s been looked at.
E385A problem with the gas valve’s first solenoid, SV1.Call a licensed plumber.
E388A problem with the bypass valve.Call a licensed plumber.
E392A fan problem: false start.Call a licensed plumber.
E393A fan problem: the fan’s signal was lost.Call a licensed plumber.
E394The fan can’t reach its target speed.Make sure nothing is blocking the vent or air intake outside. Then call.
E396The recirculation pump is running too slow.Call a licensed plumber.
E397The recirculation pump is drawing too little current.Call a licensed plumber.
E398Low water flow through the recirculation pump.Call a licensed plumber.
E399The recirculation pump went over its power limit.Call a licensed plumber.
E400The display lost communication with the heater.Call a licensed plumber.
E401The remote controller lost communication with the heater.Call a licensed plumber.
E402A communication problem between linked heaters.Call a licensed plumber.
E403The fan is running too slow.Make sure nothing is blocking the vent or air intake outside. Then call.
E411The water in the heat exchanger is overheating.Call a licensed plumber.
E412A hardware problem with the circuit board.Call a licensed plumber.
E413A flame sensor problem.Make sure nothing is blocking the vent or air intake outside, and that nothing from the list below is stored near the heater. Then call.
E414A problem with the circuit board’s flame sensor circuit.Call a licensed plumber.
E415A gas valve fault.Call a licensed plumber.
E416An internal reading fault. A.O. Smith’s checks start with the outlet temperature sensor.Call a licensed plumber.
E417A flame sensor fault.Call a licensed plumber.
E418The exhaust is running too hot.Make sure nothing is blocking the vent or air intake outside. Then call.
E420A problem with the gas valve’s second solenoid, SV2.Call a licensed plumber.
E421A problem with the pressure switch.Make sure nothing is blocking the vent or air intake outside. Then call.
E422A problem with the venturi assembly.Call a licensed plumber.
E426The condensate drain is overflowing.Put a bucket under the heater, turn the heater off, and check the condensate drain line for anything blocking it. Call if it comes back.
E427A problem with the flow control valve.Call a licensed plumber.
E428A flow sensor problem, on linked heaters only.Make sure the heater is on, with the set temperature showing, and that its water shutoff valves are open. Then call.
E429A flow control valve fault, on linked heaters only.Call a licensed plumber.

Codes You Can Usually Check Yourself

It’s a spectrum. A one time ignition lockout, a scale related flow code or a fouled vent termination outside are a reset, a descaling or a cleaning.

E036 and E038: Flame and Ignition

Start with the gas. A.O. Smith’s troubleshooting chart asks whether the gas valve to the heater is fully open and, on propane, whether there’s gas in the tank. On a new install, A.O. Smith also notes there will be air in the gas line, and it can take several tries to clear it.

If it keeps coming back, call us. A whole house tankless runs 150,000 to 199,000 BTU, so the half inch line that fed your old tank almost never covers it, and an undersized gas line is one of the install problems behind a unit that keeps throwing codes. We never want you doing gas yourself.

And if the gas valve won’t turn by hand, A.O. Smith says not to force it and never to use tools. Call a qualified service technician.

E394, E403, E413, E418 and E421: Air and Venting

For all five, one of A.O. Smith’s checks is the exhaust vent and the air intake: with the heater’s power disconnected, check them for blockages and clear anything you find. A tankless has its own vent and a matching air intake, usually PVC or stainless out a side wall. Go look at where they come out.

A.O. Smith also says to keep the area around the heater, the vent termination and the air intake free of dust and debris, and to check the intake and venting once a year for leaks, corrosion, blockages or damage.

E413 points at the air itself, too. A.O. Smith says aerosol sprays, detergents, bleach, cleaning solvents, gasoline, air fresheners, paint and varnish removers and refrigerants shouldn’t be stored or used near the water heater.

E426: Condensate Drain Overflow

Condensing models like these drain water through a condensate line. For E426, A.O. Smith says to put a bucket under the heater, then with the heater off, check the condensate drain for anything blocking it. Its maintenance list also says to make sure the drain lines slope downward and drain freely.

If the drain line is clear and the code comes back, call.

E045: The Clock Battery

E045 means the battery that keeps the clock’s time during a power outage is getting low. It can also show up when the power comes back on after an outage, and in that case A.O. Smith says to ignore it. If it isn’t from an outage, the battery is on the circuit board inside the heater, so that’s a call.

E037 and E384: A Flame That Shouldn’t Be There

Both mean the heater sees a flame when it shouldn’t. For E384, A.O. Smith says to look through the sight glass, and if there’s a flame, shut off the gas to the heater right away and don’t use it until a qualified service technician has looked at it. For E037, it says to shut the heater off and call.

Codes That Need a Plumber

For the rest, the steps in A.O. Smith’s table go inside the cabinet: wiring, sensors, the gas valve and the circuit board, some of them on live circuits. A.O. Smith’s own warning is that working on an energized circuit can cause severe injury or death from electrical shock. That’s the temperature codes (E041, E049, E050, E051, E052, E383 and E411), the gas valve codes (E385, E415 and E420), the fan codes (E392 and E393), the circuit board codes (E006, E010, E011, E412, E414 and E416), the flame sensor (E417), the venturi (E422), the valve and flow codes (E388, E427, E428 and E429), the recirculation pump codes (E396 through E399), the communication codes (E400, E401 and E402) and the high limit switches (E002).

E002 deserves a word. A.O. Smith’s table shows how to reset the high limit switch on the water outlet, but if it keeps tripping, it says to call a qualified service technician, and the automatic one on the burner door can’t be reset at all. It has to be replaced.

Before you call A.O. Smith, it asks you to write down the model and serial number from the rating plate. Have the same ready for us.

Heat exchanger, gas valve, control board and overheat faults are the other end of the spectrum, and on our own jobs those have run fifteen hundred to three thousand.

What A.O. Smith Leaves to You

A.O. Smith’s manual lists routine maintenance you can do yourself, and says to call a qualified person for any of it you can’t:

  • Check the air intake and venting once a year for leaks, corrosion, blockages or damage.
  • Keep the area around the heater, the vent termination and the air intake clear of dust, debris and anything that burns.
  • Check that the condensate drain lines slope downward and drain freely.
  • Operate the pressure relief valve now and then to make sure it works, after you check that it will discharge somewhere safe.

That last one releases hot water. If water doesn’t flow freely from the end of the discharge pipe, A.O. Smith says to turn the gas and power off and call a qualified person.

A.O. Smith’s list also includes cleaning the filter on the cold water inlet, a wire mesh screen that catches debris and needs cleaning now and then to keep the flow up. We recommend having a plumber do it. It’s a fairly simple job, though, and A.O. Smith lists it as something you can do yourself. If you’re handy and want to, follow A.O. Smith’s instructions exactly, starting with its rule for any service: turn off the power and close the gas and water valves first. Things can still go wrong. We’ve been called out to a leaking tankless filter because whoever had it apart last cross threaded a screw. If you do it yourself, the risk is yours.

Scale and Tulsa Water

A.O. Smith builds the Adapt+ two ways. The X3 models have a scale prevention cartridge in the manifold under the heater, and the M models have a plain bypass cartridge in the same spot. A.O. Smith sells the X3 cartridge separately to add to an M model.

A.O. Smith also says water conditions like excessive iron or manganese can affect how well X3 works, and suggests having a water quality expert check yours.

In Tulsa that matters. Our water is hard, and the scale it leaves narrows the heat exchanger until you get flow codes and an early failure. Descaling is maintenance you have to keep up with, and we do it in house.

Winter: Keep the Power On

The Adapt+ protects itself from freezing with heating blocks, and it will fire the burner for a short time when it needs to. A.O. Smith says that only works with electrical power to the unit, so leave it plugged in.

That protection only covers the pipes inside the heater. A.O. Smith says to protect and insulate the hot and cold pipes outside it.

If you won’t be using it for a long time, or the power goes out while it’s freezing, A.O. Smith says to drain it completely and disconnect the power. The steps are on page 55 of the manual: close the gas valve, unplug the heater, close the cold water valve, open all the hot taps until they stop running and close them, then drain the cartridge under the heater into a bucket. If you aren’t comfortable with them, call us.

To start it back up, the same page says to put the cartridge back, open the cold water valve and check for leaks before you plug it back in and open the gas. If any errors come up, A.O. Smith says to shut off the water immediately.

Do’s and Don’ts

Do

  • Write down the code and the model and serial number off the data plate.
  • Check the basics first: power, the On/Off button and the gas and water valves.
  • Keep the vent and air intake outside clear, and check them once a year.
  • Have the cold water inlet filter cleaned now and then. We recommend a plumber, though A.O. Smith lists it as something you can do yourself.
  • Have it checked once a year by a licensed technician. A.O. Smith recommends it.
  • Keep up with descaling. In Tulsa it isn’t a suggestion.
  • Leave it plugged in all winter.
  • Put in a fuel gas and carbon monoxide detector. A.O. Smith recommends one in the living areas of your home.

Don’t

  • Don’t ignore a code that keeps coming back.
  • Don’t use tools on the gas valve. If it won’t turn by hand, A.O. Smith says to call a qualified service technician.
  • Don’t open the cabinet or work on the wiring. Some of A.O. Smith’s own steps are on live circuits.
  • Don’t use it if any part has been under water. A.O. Smith says it has to be replaced.
  • Don’t store aerosols, bleach, cleaning solvents, gasoline or paint removers near it.
  • Don’t cap or plug the pressure relief valve or its discharge pipe.
  • Other than turning the gas shutoff valve, don’t touch the gas. Call a licensed plumber.

What It Costs

On our price list, tankless water heater repair runs $650 to $1,225, and tankless descaling runs $425 to $850.

Tell us the code and the model number when you book.

A.O. Smith’s Manuals and Support

Everything in the chart comes from A.O. Smith’s own documents, and these are the ones worth keeping:

A.O. Smith’s manual says to keep it with the heater. We checked this post against the manual on A.O. Smith’s site in November 2026, so if yours is a different version, go with yours.

Call Us With the Code

We service every brand, and around Tulsa we see Navien, Rinnai, Rheem, Noritz and A.O. Smith most. Our error code guides for Navien, Rinnai, Rheem, Noritz and Takagi cover the others, and our tankless error codes page shows which codes mean the same thing across brands.

Call us at (918) 800-4426 with the code and the model number. Our tankless water heater repair page has more on what we do.