Your gas water heater quit making hot water, and the light on the gas control is blinking. Count the flashes, then write down the brand and the model and serial number off the label on the heater.
We have a guide for each of four tank brands: Bradford White, A.O. Smith, Rheem and State. This page sends you to the right one and shows which flash counts mean the same thing across brands, and which don’t.
Read This First
This page and the guides it links are built from each manufacturer’s own manuals, but they’re not a replacement for them. If anything here disagrees with the manual for your heater, go with the manual.
If you smell gas, leave first, then call ONG at 800-458-4251. All four manufacturers’ manuals add: don’t try to light any appliance, don’t touch any electrical switch, and don’t use any phone in your building.
If any part of the heater has been under water, don’t use it. Rheem and State say a flooded water heater has to be replaced, A.O. Smith’s position is that it should be replaced, and Bradford White says to have a qualified service technician inspect it and replace any part of the control system that was under water.
If there’s water on the floor, shut the valve on the cold line into the top of the tank, kill the gas or the breaker, and call us. Our post on a leaking water heater covers where the water is coming from.
Find Your Brand’s Guide
Find your brand, then go to its guide. Each one has that brand’s full charts, how to tell which control you have, what you can check yourself, and which codes need a licensed plumber.
| Brand | What normal looks like on pilot models | Model and serial number |
|---|---|---|
| Bradford White | One flash, then a pause, on the older ICON control. One flash every four seconds on the newer ICON and the SIT, and one every second while the burner is on | On the rating plate. The first two letters of the serial number give the year and month it was made |
| A.O. Smith | One flash every three seconds | On the data plate, next to the gas control. Some have a QR code |
| Rheem | One blue blink every three seconds. Problems blink red | On the rating plate on the heater’s jacket |
| State | One flash every three seconds | On the rating plate, next to the gas control. Some have a QR code |
Does Yours Have a Status Light?
Not every gas water heater has one. All four brands make, or have made, models whose gas control has no status light, and none of these charts apply to those. On Rheem, that includes its Professional Classic atmospheric models, its direct vent models and its manufactured housing models.
Power vent models light themselves, have an ON/OFF switch on the gas control, and flash a different set of codes. Electric models, heat pumps and most high efficiency models either have no codes or have charts of their own, so go by the manual for those.
The Same Flash Count, Brand by Brand
These are the standing pilot charts. Most counts mean close to the same thing on all four, but not every count is on every chart. Where it says to call, that means a licensed plumber.
Normal
- Bradford White: one flash, then a three second pause, on the older ICON. One flash every four seconds on the newer ICON and SIT, or one every second while the burner is on
- A.O. Smith: one flash every three seconds
- Rheem: one blue blink every three seconds
- State: one flash every three seconds
If the light looks normal and the water is still cold, A.O. Smith and State say to check that the gas control knob is set to HOT, and Rheem says that if the knob is still at PILOT, to set it to the temperature you want.
A Solid Light or No Light
- Bradford White: a solid light means the knob was just turned to OFF, and it goes out on its own. No light means the pilot is out or the control is off
- A.O. Smith: a solid light means the pilot was lit but is now off. Wait 10 minutes for it to go out. No light means the pilot is out
- Rheem: a solid light means the pilot just went out or the knob was just turned to OFF. No light means the gas control is off, the pilot is out, or the thermopile isn’t making enough power
- State: the same as A.O. Smith
Each guide has that brand’s limits on relighting the pilot.
2 Flashes: A Weak Pilot or Thermopile
- Bradford White: a weak pilot flame or low thermopile voltage
- A.O. Smith: not enough power from the thermopile to the gas control
- Rheem: 2 red, low thermopile voltage, though the pilot is lit
- State: not enough power from the thermopile to the gas control
4 Flashes: Too Hot
- Bradford White: the tank got too hot, and the control shut down
- A.O. Smith: the water got too hot and tripped the overheat sensor
- Rheem: 4 red, the high water temperature limit tripped
- State: the water got too hot and tripped the overheat sensor
On all four, turn off the gas shutoff valve to the heater and call. A.O. Smith and State say the gas control valve has to be replaced.
5 and 7 Flashes: A Sensor or the Gas Control
- Bradford White: 5 is a temperature sensor fault on the older ICON, and an electronics, sensor or gas valve fault on the newer ICON and SIT. 7 is a fault in the gas valve’s electronics on the older ICON
- A.O. Smith: 5 is a failed sensor, and 7 is a failed gas control valve
- Rheem: 5 red is a failed water temperature sensor, and 7 red is a failed gas control
- State: 5 is a failed temperature sensor, and 7 is a failed gas control valve
These are calls on every brand.
8 Flashes: A Pilot Signal That Shouldn’t Be There
- Bradford White: on the older ICON, the control sees a pilot flame that shouldn’t be there
- A.O. Smith: the knob was turned off, but the thermopile kept making power, or the pilot valve is stuck open and the pilot is still burning
- Rheem: 8 red, a false pilot flame signal
- State: the same as A.O. Smith
Call. If the pilot is still burning with the knob off, A.O. Smith and State say to turn the main gas supply off.
9 and 10 Flashes: Ultra Low NOx Models
- Bradford White: not on its charts
- A.O. Smith: 9 is the combustion chamber temperature sensor circuit, and 10 means lint, dust or oil was detected in the combustion chamber
- Rheem: 9 red is a failed chamber sensor, and 10 red is a chamber temperature shutdown
- State: the same as A.O. Smith
3 and 6 Flashes
Only Bradford White’s older ICON uses these. 3 means the water isn’t heating enough, and Bradford White says the system will reset. 6 means a leak sensor found too much water in the drain pan, on the models that have one.
A.O. Smith’s, Rheem’s and State’s pilot charts have no 3 or 6. If you’re counting one of those on one of those brands, count again, and if it holds, call.
Power Vent Models
The power vent charts line up even more closely. On all four, 2 means the pressure switch is stuck closed, 3 means it’s open, 4 means the tank got too hot, and 5 means the control saw a flame when it shouldn’t have. 6 followed by a second number means the burner didn’t light, a switch opened, or the flame went out or showed up when it shouldn’t have. 7 is the flammable vapor sensor, and 8 followed by a second number is a sensor, electronics or gas valve fault.
For 3, Bradford White’s and Rheem’s guides list a blocked vent, so take a look at the vent where it leaves the house. For 4, turn off the gas shutoff valve, or on a Bradford White the power, and call. For 7, if you smell gas, leave first.
How We Handle the Fixes You Can Do Yourself
Our rule is simple. We recommend calling a plumber. But where your manufacturer’s manual gives you a job, like relighting the pilot or draining the tank, we won’t rule out a handy homeowner doing it. Follow the instructions exactly. Things can go wrong, and if they do, you’re taking that on yourself.
The manufacturers don’t all draw that line in the same place:
- Bradford White’s manuals say not to attempt repair of the gas control, burners or gas piping, and its FAQ says the flashing light is there to help the professional plumber troubleshoot.
- A.O. Smith’s manual gives you the steps for lighting the pilot and for its routine maintenance, and says that if you can’t do the maintenance yourself, to contact a qualified person.
- Rheem suggests a routine maintenance program for the owner, with periodic inspections by service personnel qualified in gas appliance repair, and says to contact your installer or plumbing contractor first when your heater needs service.
- State’s manuals give you the lighting and maintenance steps too, and State’s website says to have a licensed professional flush, inspect and maintain a gas tank water heater every year.
And whatever the brand: Other than turning the gas shutoff valve and following the steps in your manual, don’t touch the gas. Call a licensed plumber.
Relighting the Pilot
All four put the lighting steps on a label on the heater. A few limits show up across the brands. Don’t try it if you smell gas. Bradford White, Rheem and State say to work the gas control knob by hand only, never with tools. And if the pilot won’t stay lit after several tries, or on A.O. Smith and State the light doesn’t start flashing after three tries, turn the knob to OFF and call.
Power vent models light themselves, and Rheem says not to try to light its power vents by hand.
Rumbling, Popping and Tulsa Water
If the heater rumbles and pops when it heats up, that’s sediment, and Tulsa’s hard water makes plenty of it. Minerals crust across the bottom, and water trapped underneath flashes to steam, so it sounds like gravel in there. Each guide has its brand’s draining and flushing schedule.
Repair It or Replace It?
Age decides this more than the symptom does. Early on, thermocouples, gas valves, elements and thermostats are normal wear parts worth fixing. Past 12 years we start recommending replacement, and a tank that’s leaking isn’t repairable at any price by anybody.
Our post on tank water heater replacement covers what comes next.
What It Costs
On our price list, a pilot assembly replacement runs $350 to $675, replacing a gas control valve runs $550 to $1,050, a general water heater repair runs $450 to $900, and our flush and tune-up runs $250 to $500.
Tell us the brand, how many times the light flashes and the model number when you book.
Call Us With the Flash Count
We service every brand. The three we install are Rheem, A.O. Smith and Bradford White. If yours is a tankless, our tankless error codes page covers Navien, Rinnai, Rheem, Noritz, Takagi and A.O. Smith.
Call us at (918) 800-4426 with the flash count and the model number. Our water heater repair page has more on what we do.