Bradford White Water Heater Blinking Light: What the Flashes Mean

Bradford White gas water heater installed by Tulsa Plumbing and Remodeling, with the install date written on the tank

Your Bradford White gas water heater quit making hot water, and the light on the gas control is blinking. Count the flashes between pauses, and write down the model and serial number off the rating plate.

This post goes through what that light means on Bradford White’s gas controls: which patterns are normal, which ones need a licensed plumber, and the few things you can check yourself. If your heater is electric, our no hot water post covers that side.

Read This First

This is a guide to Bradford White’s manuals, not a replacement for them. Patterns and steps can differ from one control to the next, so if anything here disagrees with the manual for your heater, go with the manual.

Bradford White draws its own line. Its manuals say installation and service must be done by a qualified installer, a service agency or the gas supplier, and not to attempt repair of the gas control, burners or gas piping. Its FAQ says the flashing light is there to help the professional plumber troubleshoot, and that if your water heater is giving you trouble, you should contact a plumbing professional. We hold to that line all the way through this post.

If you smell gas, leave first, then call ONG at 800-458-4251. Bradford White’s manual adds: don’t try to light any appliance, don’t touch any electrical switch, and don’t use any phone in your building. Call from a neighbor’s phone.

If any part of the heater has been under water, don’t use it. Bradford White says to have a qualified service technician inspect it and replace any part of the control system, the gas control included, that was under water.

If there’s water on the floor, shut the valve on the cold line into the top of the tank, kill the gas or the breaker, and call us. Our post on a leaking water heater covers where the water is coming from.

One thing that isn’t a leak: Bradford White says that when the tank fills with cold water, condensation forms on it and drips onto the burner with a sizzling sound. That’s normal, and it goes away once the tank heats up.

Which Control Do You Have?

Bradford White’s current manual for its standard gas models, atmospheric vent and direct vent, lists three gas controls, and only two of them have a status light:

  • The ICON System control by Resideo. The manual shows two versions: an older one with a small round light marked STATUS, and a newer one with a rectangular STATUS window whose light shows green, yellow or red.
  • The ICON System control by SIT, with its own status light.
  • A White Rodgers mechanical control, which has no status light. None of the charts below apply to it.

Older Bradford Whites can have a mechanical control with no light at all, too. The manual has pictures of each control on its lighting and temperature pages, so compare yours.

Power vent, power direct vent and the high efficiency eF models need electric power, light their own pilot and have an ON/OFF switch on the gas control. Their light works differently, and their chart is further down.

Bradford White’s standard electric models don’t have codes at all. Its AeroTherm heat pumps and its ICON E electric models show codes of their own, and their manuals cover those.

Find Your Model and How Old It Is

The model and serial number are on the rating plate on the heater. The first two characters of the serial number are the year and the month it was made: the first letter is the year, and the second is the month, starting with A for January. Some letters are skipped, so use the chart. The year letters repeat every 20 years, so an A in the first spot means 2004 or 2024.

Bradford White’s My Water Heater page has the full chart, and you can type your serial number in there to get the date it was made.

How to Read the Light

Bradford White’s charts count flashes, then a three second pause, and the pattern repeats. Some patterns are normal, and they differ by control:

  • Older ICON, with the round light: one flash, then a three second pause, means the pilot is lit and the heater isn’t heating right now. A quick double flash, like a strobe, then a pause, means it’s heating.
  • Newer ICON and SIT: one flash every four seconds means the pilot is lit and the burner is off. One flash every second means the burner is on.
  • On any of them, a light that stays on solid, red on the newer ICON, means the knob was just turned to OFF. It isn’t a fault, and it goes out on its own.

Bradford White Status Light Chart

Here are the patterns that point to a problem on the atmospheric vent and direct vent models, from the charts in Bradford White’s owner manuals, in plain English. Where it says to call, that means a licensed plumber.

FlashesWhat it meansWhat you can do
No lightThe pilot is out, or the control is off.See Relighting the Pilot, below.
2Two separate flashes, then the pause: a weak pilot flame or low thermopile voltage, so the burner won’t come on. On the newer ICON the light is yellow. The older ICON’s chart says it resets once the pilot flame is strong enough.If it doesn’t clear on its own, call.
3On the older ICON, the water isn’t heating enough. Bradford White says the system will reset.If it keeps coming back, call.
4The tank got too hot, and the control shut down. On the newer ICON the light is red.Turn off the gas shutoff valve to the heater and call. Bradford White says to do both if it overheats.
5On the older ICON, a temperature sensor fault. On the newer ICON and the SIT, an electronics, sensor or gas valve fault, and the newer ICON’s light is red.Call a licensed plumber.
6On the older ICON, a leak sensor found too much water in the drain pan. Only some models have one.Look for water in the pan. If it’s there, shut the valve on the cold line into the top of the tank, kill the gas, and call.
7On the older ICON, the gas valve’s electronics have a fault.Call a licensed plumber.
8On the older ICON, the control sees a pilot flame that shouldn’t be there.Call a licensed plumber.

Power Vent, Power Direct Vent and eF Models

On these models, normal looks like this: one short flash every four seconds is stand-by, a light that alternates bright and dim is heating, and a short flash every two seconds means an accessory module put the heater in idle. Careful: here, a short flash every second is not heating. It’s the first fault in the chart.

Some of their codes come in two parts: a group of flashes, then a second group, then the three second pause. In the chart, 6, then 1 means six flashes followed by one.

FlashesWhat it meansWhat you can do
No lightNo power to the control, or its switch is off.Check that the heater has power. If the light stays off, call.
Short flash every secondThe pilot signal was weak on the last call for heat.Call a licensed plumber.
2The pressure switch is stuck closed.Call a licensed plumber.
3The pressure switch or the blower temperature switch is open. Bradford White’s list of causes starts with a blocked vent.Take a look at the vent where it leaves the house. Bradford White’s website says to make sure vents aren’t blocked by snow, ice or debris. Then call.
4The tank got too hot. Bradford White says the system must be reset.Turn off the power to the heater and call. Bradford White says to do both if it overheats.
5The control sees a pilot flame that shouldn’t be there.Call a licensed plumber.
6, then 1The pilot didn’t light. Bradford White says it resets itself after 5 minutes.If it keeps coming back, call.
6, then 2The pressure switch or blower temperature switch opened while the burner was on. Bradford White’s causes include a blocked vent and wind at the vent outside. It resets itself after 5 minutes.Take a look at the vent outside for snow, ice or debris. If it keeps coming back, call.
6, then 3The pilot flame went out. It resets itself after 5 minutes.If it keeps coming back, call.
6, then 4The control sensed a pilot flame that shouldn’t be there. It resets itself.Call a licensed plumber.
7The flammable vapor sensor tripped.If you smell or suspect flammable vapors, Bradford White says to leave the area right away and contact a service professional. Otherwise, call.
8, then 1The flammable vapor sensor is out of spec. Bradford White lists a possible short.Call a licensed plumber.
8, then 2A temperature sensor fault.Call a licensed plumber.
8, then 3An electronics fault.Call a licensed plumber.
8, then 4A gas valve fault.Call a licensed plumber.

Bradford White’s damper, fan assist and manufactured home models have charts of their own, and some of their codes mean something different, so go by the manual for those.

Relighting the Pilot

Bradford White prints the lighting instructions on a label on the heater, and its FAQ says a pilot should only need lighting once, when the heater is installed and set up.

We recommend a plumber. If you relight it yourself, follow the label on your heater exactly. The risk is yours.

Bradford White’s label also says: if you smell gas, stop. Use only your hand on the gas control knob, never tools, and if it won’t push in or turn by hand, don’t try to repair it, call a qualified service technician. If the knob doesn’t pop back out when you let go, stop and call right away. If the pilot won’t stay lit after several tries, turn the knob to OFF and call. And its FAQ says pilot outages that keep happening are for a plumbing professional.

Codes That Need a Plumber

Most of the rest comes down to a part: the pilot or thermopile, a temperature sensor, the gas valve or its electronics, and on a power vent, the pressure switch, the blower or the flammable vapor sensor. Bradford White says not to attempt repair of the gas control, burners or gas piping, and to refer repairs to a qualified service technician.

When you call, have the flash count, the model and the serial number ready.

Repair It or Replace It?

Age decides this more than the symptom does. Early on, thermocouples, gas valves, elements and thermostats are normal wear parts worth fixing. Past 12 years we start recommending replacement, and a tank that’s leaking isn’t repairable at any price by anybody.

The serial number tells you how old yours is. Our post on tank water heater replacement covers what comes next.

Bradford White’s Maintenance List

Bradford White’s manual lists the maintenance its gas heaters need and says a qualified service technician should do it. Its website says maintenance should be done by a plumbing or HVAC professional, and its FAQ says to ask your plumbing professional about draining the tank. So there’s no do-it-yourself list in this one. Here’s what’s on Bradford White’s:

  • Drain off a gallon of water every month to remove silt and sediment.
  • Check the temperature and pressure relief valve at least once a year. Bradford White warns that lifting its lever releases hot water under pressure.
  • Inspect the anode rod every 2 years, and replace it when needed.
  • Inspect the vent system at least once a year for exhaust leaks.
  • Clean the vent pipe and the screen inside the vent hood.
  • Check the thermostat once a year.
  • Check the main burner and pilot flames, and once a year, clean the burner and the combustion chamber.
  • Keep the air slots at the bottom of the jacket open and clean.

Two of Bradford White’s rules apply every day, not just at service time: keep gasoline, paint thinner and anything else that burns away from the heater, and don’t block the air slots at the bottom front of it.

Rumbling, Popping and Tulsa Water

If the heater rumbles and pops when it heats up, that’s sediment, and Tulsa’s hard water makes plenty of it. Minerals crust across the bottom, and water trapped underneath flashes to steam, so it sounds like gravel in there. That’s what the monthly gallon on Bradford White’s list is for.

The Relief Valve and Expansion

If water drips out of the pipe on the side of the tank, that’s the temperature and pressure relief line, and the valve is doing its job. Bradford White says a valve that discharges now and then may be thermal expansion in a closed water system, and says never to plug its outlet. A steady drip means high pressure, a waterlogged expansion tank, or a thermostat set too hot. Never cap that pipe.

Bradford White recommends an installation that allows for thermal expansion, through an expansion tank or other means. A pressure reducing valve or check valve on your main makes a closed system, and heated water has nowhere to expand. Without an expansion tank you get a dripping T and P valve and banging pipes. The bladder gives up around 5 to 10 years, so we check it on every water heater visit.

Do’s and Don’ts

Do

  • Count the flashes and write down the model and serial number off the rating plate.
  • Use the serial number to find out how old the heater is.
  • Keep the area around the heater clear of anything that burns.
  • Keep the air slots at the bottom of the jacket clear.
  • Have Bradford White’s maintenance list done by a qualified technician.

Don’t

  • Don’t ignore a code that keeps coming back. Call.
  • Don’t try to repair the gas control, burners or gas piping. Bradford White says to leave repairs to a qualified service technician.
  • Don’t use tools on the gas control knob.
  • Don’t use it if any part has been under water.
  • Don’t plug or cap the relief valve’s discharge pipe.
  • Other than turning the gas shutoff valve and following the lighting label, don’t touch the gas. Call a licensed plumber.

What It Costs

On our price list, a pilot assembly replacement runs $350 to $675, replacing a gas control valve runs $550 to $1,050, and a general water heater repair runs $450 to $900.

Tell us how many times the light flashes and the model number when you book.

Bradford White’s Manuals and Support

Everything in the charts comes from Bradford White’s own documents, and these are the ones worth keeping:

We checked this post against the manuals on Bradford White’s site in November 2026, so if yours is a different version, go with yours.

Call Us With the Flash Count

We service every brand, and Bradford White is one of the three we install, along with Rheem and A.O. Smith. Our Rheem and A.O. Smith guides cover those brands, and we have one for State too. Our water heater blinking light page compares all four. If yours is a tankless, our tankless error codes page covers Navien, Rinnai, Rheem, Noritz, Takagi and A.O. Smith.